Intel P3600 can't format between LBAFs

$
0
0

I have an Intel P3600 drive formatted to LBAF=2 (lbaf  2 : ms:16  ds:9  rp:0x2 (in use)). I can no longer format to different LBAFs. Drive FW is 8DV101F0, which I believe is the latest. This persists across reboots, power cycles, etc.

 

[root@VLUNnvme ~]# nvme id-ns /dev/nvme2n1 -n 1

NVME Identify Namespace 1:

nsze    : 0x2e9390b0

ncap    : 0x2e9390b0

nuse    : 0x2e9390b0

nsfeat  : 0

nlbaf   : 6

flbas   : 0x12

mc      : 0x1

dpc     : 0x11

dps     : 0

nmic    : 0

rescap  : 0

fpi     : 0

nawun   : 0

nawupf  : 0

nacwu   : 0

nabsn   : 0

nabo    : 0

nabspf  : 0

nvmcap  : 0

nguid   : 00000000000000000000000000000000

eui64   : 0000000000000000

lbaf  0 : ms:0   ds:9  rp:0x2

lbaf  1 : ms:8   ds:9  rp:0x2

lbaf  2 : ms:16  ds:9  rp:0x2 (in use)

lbaf  3 : ms:0   ds:12 rp:0

lbaf  4 : ms:8   ds:12 rp:0

lbaf  5 : ms:64  ds:12 rp:0

lbaf  6 : ms:128 ds:12 rp:0

 

 

[root@VLUNnvme ~]# nvme format /dev/nvme2n1 -lbaf 1

Success formatting namespace:1

 

[root@VLUNnvme ~]# nvme id-ns /dev/nvme2n1 -n 1

NVME Identify Namespace 1:

nsze    : 0x2e9390b0

ncap    : 0x2e9390b0

nuse    : 0x2e9390b0

nsfeat  : 0

nlbaf   : 6

flbas   : 0x12

mc      : 0x1

dpc     : 0x11

dps     : 0

nmic    : 0

rescap  : 0

fpi     : 0

nawun   : 0

nawupf  : 0

nacwu   : 0

nabsn   : 0

nabo    : 0

nabspf  : 0

nvmcap  : 0

nguid   : 00000000000000000000000000000000

eui64   : 0000000000000000

lbaf  0 : ms:0   ds:9  rp:0x2

lbaf  1 : ms:8   ds:9  rp:0x2

lbaf  2 : ms:16  ds:9  rp:0x2 (in use)

lbaf  3 : ms:0   ds:12 rp:0

lbaf  4 : ms:8   ds:12 rp:0

lbaf  5 : ms:64  ds:12 rp:0

lbaf  6 : ms:128 ds:12 rp:0