I have an Intel P3600 drive formatted to LBAF=2 (lbaf 2 : ms:16 ds:9 rp:0x2 (in use)). I can no longer format to different LBAFs. Drive FW is 8DV101F0, which I believe is the latest. This persists across reboots, power cycles, etc.
[root@VLUNnvme ~]# nvme id-ns /dev/nvme2n1 -n 1
NVME Identify Namespace 1:
nsze : 0x2e9390b0
ncap : 0x2e9390b0
nuse : 0x2e9390b0
nsfeat : 0
nlbaf : 6
flbas : 0x12
mc : 0x1
dpc : 0x11
dps : 0
nmic : 0
rescap : 0
fpi : 0
nawun : 0
nawupf : 0
nacwu : 0
nabsn : 0
nabo : 0
nabspf : 0
nvmcap : 0
nguid : 00000000000000000000000000000000
eui64 : 0000000000000000
lbaf 0 : ms:0 ds:9 rp:0x2
lbaf 1 : ms:8 ds:9 rp:0x2
lbaf 2 : ms:16 ds:9 rp:0x2 (in use)
lbaf 3 : ms:0 ds:12 rp:0
lbaf 4 : ms:8 ds:12 rp:0
lbaf 5 : ms:64 ds:12 rp:0
lbaf 6 : ms:128 ds:12 rp:0
[root@VLUNnvme ~]# nvme format /dev/nvme2n1 -lbaf 1
Success formatting namespace:1
[root@VLUNnvme ~]# nvme id-ns /dev/nvme2n1 -n 1
NVME Identify Namespace 1:
nsze : 0x2e9390b0
ncap : 0x2e9390b0
nuse : 0x2e9390b0
nsfeat : 0
nlbaf : 6
flbas : 0x12
mc : 0x1
dpc : 0x11
dps : 0
nmic : 0
rescap : 0
fpi : 0
nawun : 0
nawupf : 0
nacwu : 0
nabsn : 0
nabo : 0
nabspf : 0
nvmcap : 0
nguid : 00000000000000000000000000000000
eui64 : 0000000000000000
lbaf 0 : ms:0 ds:9 rp:0x2
lbaf 1 : ms:8 ds:9 rp:0x2
lbaf 2 : ms:16 ds:9 rp:0x2 (in use)
lbaf 3 : ms:0 ds:12 rp:0
lbaf 4 : ms:8 ds:12 rp:0
lbaf 5 : ms:64 ds:12 rp:0
lbaf 6 : ms:128 ds:12 rp:0